HW0482309
92
To measure the external resistance value, move the manipulator so that the torch will be close
to the jig stand. Then, use the cable for resistance measurement to connect the torch tip end
and the jig stand where base metal to be welded is set, as shown in the following figure.
For the cable for measurement, use a conductor of 38 mm
2
×
0.5 m (as thick and short as
possible).
Securely connect the chip body at the torch end tip and the jig stand using a bolt or vice.
Fig. 14.2.1 Connection of Cable for Resistance Measurement
Jig stand
Connect in this order: torch cable
→
wire feeder
→
positive (+) side power cable
→
welder
38 mm
2
×
0.5 m
ノズル チップをトーチからはずし
ワイヤを引っ込める
M6ボルトで 抵抗測定用ケーブル
をチップボディに接続する
ボルト または万力で 抵抗測定用ケーブル
のもう一方を冶具台に接続する
Use a bolt M6 to connect the cable for
resistance measurement to the chip body.
Use a bolt or vice to connect the other end of the
cable for resistance measurement to the jig stand.
Cable for resistance
measurement
Torch
Remove the nozzle and chip from the
torch and pull back the wire.
Connect in this order: negative (-) side
power cable
→
welder
c
d
e