HW0482309
38
(ON/OFF) can be changed. ON and OFF are switched with each pressing of the
button No.13 “+” or “-“.
(4)
After changing the setting, press the button No.9 “Common P.R.M. Select” or leave it
without doing anything for 10 seconds to return to the standby display.
<Example>
When the No.11 of D parameter D-1 is ON (enabled):
Press the button No.14 “Record” for 3 seconds or more to save the changed value.
Do not turn OFF the breaker until the LED indicator lights again when the “Record”
button was pressed.
4.2.6
Saving Welding Conditions
When the parameter set value is changed by the operations on the panel, the LED indicator of
the "Record" blinks.
The following describes how to save the settings.
(5)
Referring to 4.2.2, specify the file number where the data are to be saved.
(6)
Press the button No.14 "Record" for 3 seconds or more, and the panel LED indicators
are extinguished, while only the indicator of the "Record" lights.
(7)
When the saving is completed, the display returns to the status where the conditions
were saved.
While the data is being saved, the panel LED indicators are extinguished. If the power
supply is turned OFF while the LED indicators are extinguished, the data cannot be
correctly saved. Confirm that the panel LED indicators light again before turning OFF
the power supply.
For P parameters, the changed data has been validated at the same time the
change is made. However, when the welding type is changed or the power supply
switch of the welder is turned OFF, the changed data will be lost.
The changed data are overwritten on the data of the file where the data is to be
stored.
4.2.7
Local Mode
Select either one of user file: File No.1, No.2, or No.3 and press the "Local" button, and the
"Local" LED indicator lights. When the “Local” LED indicator lights, the status is in the Local
mode.
In the Local mode, welding can be performed with the welding voltage and current command
values set on the welder panel.
(1)
Press the button No.8 “Common P.R.M. Select”, and the voltage command value can
be changed. Use the button No.13 “R”, “L”, “+”, or “-“ to change the value.
(2)
Press the button No.11 “P.R.M. Set”, and the current command value can be changed.
Use the button No.13 “R”, “L”, “+”, or “-“ to change the value.
V A Wire m/min Type