HW0482309
40
4.2.10
Display of Motor Current
The motor current of rotating feeding motor can be displayed in “Wire m/min” indicator by
setting D parameter D1-5 to OFF. During the standby status, it indicates the command of wire
feeding amount (m/min).
When the indicator displays the motor current, “A” is indicated at the third digit of the indicator.
In the figure above, the motor current is 0.5 A.
When the indicator does not display “A” at the third digit, D parameter D1-5 is set to ON status,
and the indicator shows the fed-back speed of wire feeding.
4.2.11
System Reset
System Reset initializes all
the setting data in the welder. Reset the system only when the
software is updated or initialization or when Memory Error (Error 14) occurs.
Be sure that executing System Reset initializes all the internal data.
If some data must be retained, write them down on a sheet of paper beforehand.
The data cannot be restored after initialization.
The following describes how to reset the system.
(1)
Press the button No.9 "Common P.R.M. Select" during standby status. The indicator
No.1 voltmeter (V) displays "C.00" blinking, and the indicator No.3 "Wire m/min" (WF)
displays the parameter value lighting.
(2)
Use the button No.13 “+” or “-“ to increase and display the parameter “C23”.
(3)
Press the button No.11 “P.R.M. Set”, and the parameter value on the indicator No.3
“Wire m/min” blinks. Change the setting value of parameter “C23” to “2004”. When
V A Wire m/min Type
V
A
Wire m/min
Type
V
A
Wire m/min
Type
V
A
Wire m/min
Type
V
A
Wire m/min
Type