HW0482309
64
Table 9-2 Fault Analyses for Welding Section
Fault Cause Remedy
The welding torch operations are
not correct.
The wire stickout of the welding
wire is too short.
Extend it a little. Change the
welding torch angle.
The welding conditions are not
correct.
Check that the welding voltage set
value is not too large or that the
wire feeding set value is not too
small.
Chips are defective.
Check that the chip hole is worn
and its inner diameter has become
excessive. Also check for defect
on the chip inner side.
Welding current conduction is not
perfect.
Check the connections and the
current conduction contacting
section of the base metal to
confirm the current conduction.
Burnback occurs.
(The welding wire sticks
to the end tip of the
chip.)
The welding wire almost buckles.
Pull the welding wire from the
inside of the conduit and pass the
welding wire again through the
conduit.
9.3
Cause and Remedy of Electrical Circuit Section
Faults
Table 9-3 Fault Analyses for Electrical Circuit Section
No. Fault
Cause
Remedy
1
Power supply indicator lamp does
not light even if the power supply
switch is turned ON.
Power supply indicator lamp
failure, improper contact
Check contacting
sections. Replace the
power supply
indicator lamp.
Cooling fan or control circuit
failure
Check the cooling fan
and the printed board
(MB)-011, (PS)-004.
Power supply
indicator lamp
lights.
Fuse F1, F2 (5A) blown
Investigate the cause
and replace the fuse.
2
Cooling fan
does not
rotate even if
power supply
switch is
turned ON.
Power supply
indicator lamp
does not light.
Power supply indicator lamp
failure, improper contact
Check contacting
sections. Replace the
power supply
indicator lamp.
Содержание MOTOWELD-E500-6N3
Страница 22: ...HW0482309 22 Fig 2 3 Connections on the Welding side...