HW0482309
47
D-2
Display
No.
Contents ON
OFF
Default
Setting
1
External resistance
calibration
*1
Compensated with
external resistance
value set to C.08
parameter
Disabled
OFF
2
Touch start
User file 1
Enabled Disabled
(normal start)
OFF
3
Touch start
User file 2
Enabled Disabled
(normal start)
OFF
4
Touch start
User file 3
Enabled Disabled
(normal start)
OFF
5
ON
6
ON
7
ON
8
ON
9
OFF
10
OFF
11
OFF
12
OFF
13
ON
14
Reserved for system
(Do not change.)
ON
15
Error Latch
Error Latchs until
TURN OFF.
Error occurs during
error condition.
OFF
16
Reserved for system
Reserved for system (Do not change.)
OFF
・
For aluminum welding, set end event "D1- 4" to "enabled" (ON) since automatic crater
processing is effective. Set Timer instruction(about 2 seconds) after ARCOF instruction,
since crater time is about 2 seconds.
・
For synergic voltage, the voltage that Yaskawa deems adequate is specified as 100%.
Changing it by 10%, voltage varies by approx. 1V. (Example: In case of 20V at 100%, it
becomes 19V and 21V at 90% and 110%, respectively. The percentage (%) can be
changed in the range between 50% and 150% (±5V).) The percentage (%) that is set
at robot synergic voltage is displayed on the welder in the unit of V.
・
To enable the calibration for the external resistance value, the external resistance value
must be measured. For measurement of the external resistance value under your
operation conditions, refer to "14 Calibration for External Resistance”.
・
When aluminum welding "Type212,Type214" is selected, note that "Touch arc start
enabled" at D2-2,D2-3,D2-4=OFF.
*1 After saving conditions, turn OFF the welder and ON again to enable D parameters.
Содержание MOTOWELD-E500-6N3
Страница 22: ...HW0482309 22 Fig 2 3 Connections on the Welding side...
Страница 111: ...HW0482309 111 Left Side Face...