HW0482309
68
10.2
Meaning and Function of Pr (RC2) Terminal
The following describes the line number of the connection terminal stand and corresponding
signals.
(1)
TB2 Terminal
*1 R indicates the robot side while W indicates the welder side.
The external meters connected to the TB2 terminal are analog meters of ammeter
(600A /60mV) and voltmeter (75V). Values of the ten's volts for wire stick or ground
detection at the robot controller’s side may be displayed in the analog voltmeter,
which is not a failure of the device.
CAUTION
•
The output voltage (600A/60mV) of the ammeter terminal is different
from the MOTOWELD-E350II.
No.
Connection
Terminal
Stand Line
No.
Signal
Meaning
Function
Directi
on
*1
1
209
2
211
Ammeter
terminal
Outputs
600A, 60mA.
W
→
R
3
526
4
527
Voltmeter
terminal
Directly
outputs the
output
voltage.
W
→
R
5
-
6
-
Reserved - -