HW0482309
35
4.2.2
User Files
The conditions changed by the P parameter concerning any welding type are saved in the
user files: File No. 1, File No. 2, and File No. 3.
Also, the user file can be called up from the robot controller to perform welding.
The P parameter cannot be changed or saved unless the user file is selected (No File status).
(1)
When the content of P parameter is to be changed, confirm that the user file can be
changed by the panel operation (D1 parameter D1-11=OFF), then select the user file:
File No. 1, 2, or 3. The File No. is changed each pressing of No.16 “User File Select”
button, and the LED indicator of selected file lights. The File No. is changed as: No
File
File No.1
File No.2
File No.3.
(2)
Press the button No.12 “Weld.Type” to change the welding type (Type).
Refer to 4.2.1 for details on changing of the welding type.
(3)
Press the button No.8 “P.R.M. Select” to display the P parameter number.
* When the conditions are changed, the LED indicator “Record” blinks.
Press the button No.14 “Record” button for 3 seconds or more to save the changed
value.
Do not turn OFF the breaker until the LED indicator lights again when the “Record”
button was pressed.
When the welding type which is set in the user file is changed, the P parameter is
initialized and everything becomes the value at 100 %.
4.2.3
Changing P Parameters
For details on the P parameter, refer to 4.3.
The P Parameter can be changed only when the user file: File No.1, No.2, or No.3 is selected.
In this modification, the internal data of the selected welding type are multiplied by the
modification ratio.
Follow the instructions to change P parameter value as follows:
(1)
Press the button No.8 "P.R.M. Select" during standby status. The indicator No.1
voltmeter (V) displays "P.00" blinking, and the indicator No.3 "Wire m/min" (WF)
displays the parameter value lighting.
(2)
Press the button No.13 "L" or "R" button to change the number of blinking digits to
one. Press the button No.13 "L" button to move the blinking to the left, and press the
button No.13 "R" to move the blinking to the right.
(3)
Using the button No.13 “L” or “R”, move the blinking digit to the number to be
changed.
(4)
Use the button No.13 “+” or “-“ to increase or decrease the value.
(5)
Press the button No.11 “P.R.M. Set”, and the parameter value on the indicator No.3
“Wire m/min” blinks. The set value of parameter is ready to be changed. Change the
set value in the range between 10 and 200 %.
For changing the parameter number, press the button No.11 “P.R.M. Set” again.