HW0482309
66
10
Robot Interface Signals
10.1
Specifications of Robot Interface Signals
The following table shows the correspondence of the pin number and the signal of connector
CON3 (26 pins).
For signal systems, refer to "11. Connection System Diagram."
No.
Correspo
nding Pin
No. of
Connector
Signal
Meaning
Function
Direction
*1
Signal Form
1
A – B
(OV)
Arc voltage
adjustment
instruction
Gives the compensation value of the arc
voltage when set to
"
Synergic.
"
(When set to
"
independent,
"
the arc volt-
age is sent directly.)
R
→
W
Analog
voltage input
of 0V to 14V
2
C – D
(OV)
Welding
current
instruction
Gives the setting value of the output current
of the welder (wire feeding amount).
R
→
W
Analog
voltage input
of 0V to 14V
3
F – G
Wire
inching
instruction
Performs the wire inching.
R
→
W
Contact input
(Valid at
closed)
4
H – J
Wire
retract
instruction
Withdraws the wire.
R
→
W
Contact input
(Valid at
closed)
5
K – L
ARCON/
ARCOF
instruction
Instructions in starting/stopping of the
welding.
R
→
W
Contact input
(Valid at
closed)
6
M – N
(-)
Wire stick
detection
Sends the output terminal voltage of the
welder.
The wire stick detection voltage (approx. 14V)
is input from the robot side.
W
→
R
Welder output
voltage
(Analog value)
7
P – E
(COM)
Arc
occurrence
detection
Outputs when the current is detected
continuously for 16 ms after the welding start
is pre-flown. After the output, stops outputting
if the current is not detected continuously for
48 ms. Repeats this until the output is
stopped when the wire stick prevention
voltage ends.
W
→
R
Contact
output
(Valid at
closed)
8
R – E
(COM)
Arc failure
detection
(1) Outputs when the arc start is not detected
for 1.5 seconds after the welding start is
pre-flown.
(2) After the arc start is detected within 1.5
seconds after the welding start is
pre-flown, outputs when the arc start is
not detected for 0.6 seconds.
(After detection, self-maintains until the
W
→
R
Contact
output
(Valid at
closed)