HW0482309
24
type gas cylinder. If the regulator is connected to a siphon type gas cylinder, the
contents of the cylinder are not gaseous and enter the regulator as remaining
liquefied. In such a case, the pressure reduction mechanism of the regulator cannot
be operated. The type of gas cylinder can be distinguished by cylinder color
according to the cylinder’s manufacturer. Contact the gas seller for details.
The safety valve operates when the pressure goes extremely high. When the valve
operates, stop operation immediately, confirm the reason, and take appropriate
corrective actions to prevent that the same error occurs again.
(3)
Quality of Gas for Welding
Moisture or impurity in the carbon dioxide gas or argon gas used to shield welding
arcs adversely influences welding. High purity and low moisture gas must be used.
Use MAG gas
containing 80% argon and 20% carbon dioxide gas for mixed gas. The
gas mixing ratio of MAG gas is content, which contributes to constant welding quality.
Especially for pulse welding, improper pulse welding will be resulted if the argon gas
ratio is less than 80%.
Use carbon dioxide gas
designated as “for welding” or what conforms to Class 3
specified in JIS-K1106 (moisture content 0.005% or less) or the equivalent.
Avoid using carbon dioxide gas containing moisture more than 0.005%, not only for
the adverse effect on welding, but also because it may cause clogging in the gas
regulator if the water content freezes.
(4)
Gas Regulator with Flow Meter
Use gas regulator with flow meter suitable for the gas to be used. The following table
shows the examples of the gas regulator
Table. 2-2 Gas Regulator with Flow Meter
No. Type
Applicable
Gas
Remarks
1
FCR-2505A CO
2
, MAG
Meter: Indicates secondary pressure and
flow amount.
Heater: 100 VAC
*1
, 190 W
2
FCR-225 CO
2
, MAG, Ar
Meter: Indicates primary pressure and
float-type flow amount.
Heater: 100 VAC
*1
, 190 W
*1 The power supply for the heater is not provided with the welder.