2.2 Basic Module
2.2.5 Built-in SVB Module
2-43
2
Specifications and Functions
2.
Link Assignment Tab Page
The data of the slave devices (MECHATROLINK connected devices such as SERVOPACK, inverter, and distrib-
uted I/O) are displayed on the
Link Assignment
Tab.
The items shown on the
Link Assignment
Tab are as follows. You can change the settings or delete the data station by
station on this tab. Always save the settings to the flash memory after changing them.
Deleting a Station Assignment
Click any cell in the row of the station to be deleted, and select
Edit
-
Assignment Delete
from the main menu.
Care must be taken when deleting a station assignment. The deletion is irreversible.
*****I/O and *****SERVO in Type
The following slave devices (I/O Modules) do not have model codes. Therefore, “
*****I/O
”(wild card I/O) will be displayed in
TYPE
for these devices after execution of self-configuration.
• JEPMC-IO350
• JAMSC-120DAI53330
• JAMSC-120DAI73330
• JAMSC-120DAO83330
• JAMSC-120DRA83030
For a servo with customized specifications that could not be recognized by self-configuration, “
*****SERVO
” (wild card
servo) will be displayed in
TYPE
.
Select a correct device type in the Link Assignment Tab Page for the devices with
*****I/O
or
*****SERVO
displayed in
TYPE
.
Item
Description
Options and Precautions on Settings
ST #
Station number
The station number set here must be the same as the
number set using rotary switches.
TYPE
Slave device connected at the station
Select the device type from the pull-down list.
D
I/O register’s enable/disable status
: Enabled
: Disabled
Click the button to switch the status.
INPUT, SIZE
The leading input register number (
INPUT
) and
the number of input registers in words (
SIZE
).
The maximum number of input registers will be
automatically set in
SIZE
.
When setting, be careful not to overlap the register
range among stations. The register numbers that can be
set are in the range between the leading register number
and the ending register number in the Module Configu-
ration Definition Window.
OUTPUT, SIZE
The leading output register number (
OUTPUT
)
and the number of input registers in words
(
SIZE
). The maximum number of output regis-
ters will be automatically set in
SIZE
.
When setting, be careful not to overlap the register
range among stations. The register numbers that can be
set are in the range between the leading register number
and the ending register number in the Module Configu-
ration Definition Window.
SCAN
Scan type used for synchronization with CPU.
High
: High-speed scan
Low
: Low-speed scan
Select either
High
or
Low
. When
TYPE
is set to a
SERVOPACK, fixed to
High
.
Comment
(Station name)
−
Enter a comment of up to 32 characters for each station.
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...