6.2 Communication with Other MP Series
6.2.3 When MP2300S Acts as Master (I/O message communication function is used)
6-45
6
Ethernet Communications
Parameter list setting example for message receive function
An example of a parameter list setting when receiving messages from a transmit source using the connection with
connection numbers = 5 and 6 follows:
Note: N: Input, OUT: Output, SYS: For system use
Note: N: Input, OUT: Output, SYS: For system use
Table 6.10 Parameter List Setting Example 1 (parameter list start address Param = DA00000)
Register
Number
Setting
Value
Parameter
Number
IN/OUT
Remarks
DW00000
–
PARAM00
OUT
Process result
DW00001
–
PARAM01
OUT
Status
DW00002
00005
PARAM02
IN
Connection number = 5 (For receiving read operation)
DW00003
–
PARAM03
OUT
Option
DW00004
–
PARAM04
OUT
Function code
DW00005
–
PARAM05
OUT
Data address
DW00006
–
PARAM06
OUT
Data size
DW00007
–
PARAM07
OUT
Remote CPU number
DW00008
00000
PARAM08
IN
Coil offset = 0 word
DW00009
00000
PARAM09
IN
Input relay offset = 0 word
DW00010
00000
PARAM10
IN
Input register offset = 0 word
DW00011
00000
PARAM11
IN
Holding register offset = 0 word
DW00012
00000
PARAM12
IN
Writable address lower limit = MW00000
DW00013
65534
PARAM13
IN
Writable address upper limit = MW65534
DW00014
–
PARAM14
SYS
Reserved by the system. (Zero clear at startup)
DW00015
–
PARAM15
SYS
Reserved by the system.
DW00016
–
PARAM16
SYS
Reserved by the system.
Table 6.11 Parameter List Setting Example 2 (parameter list start address Param = DA00000)
Register
Number
Setting
Value
Parameter
Number
IN/OUT
Remarks
DW00000
–
PARAM00
OUT
Process result
DW00001
–
PARAM01
OUT
Status
DW00002
00006
PARAM02
IN
Connection number = 6 (For receiving write opera-
tion)
DW00003
–
PARAM03
OUT
Option
DW00004
–
PARAM04
OUT
Function code
DW00005
–
PARAM05
OUT
Data address
DW00006
–
PARAM06
OUT
Data size
DW00007
–
PARAM07
OUT
Remote CPU number
DW00008
00000
PARAM08
IN
Coil offset = 0 word
DW00009
00000
PARAM09
IN
Input relay offset = 0 word
DW00010
00000
PARAM10
IN
Input register offset = 0 word
DW00011
00000
PARAM11
IN
Holding register offset = 0 word
DW00012
00000
PARAM12
IN
Writable address lower limit = MW00000
DW00013
65534
PARAM13
IN
Writable address upper limit = MW65534
DW00014
–
PARAM14
SYS
Reserved by the system. (Zero clear at startup)
DW00015
–
PARAM15
SYS
Reserved by the system.
DW00016
–
PARAM16
SYS
Reserved by the system.
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...