3.2 Basic Module Connections
3.2.5 RLY OUT Connector Details
3-23
3
Mounting and Wiring
3.2.5 RLY OUT Connector Details
The RLY OUT connector is a terminal for outputting state and NO contact relay output. A circuit between terminals is
short-circuited when RDY LED is lit, and opens when it is unlit.
Note: A state when RDY LED is lit indicates that a controller is operating normally. It does not indicate that an
user program is running.
( 1 ) RLY OUT Connector Specifications and Pin Arrangement
The following table provides the RLY OUT connector specifications.
The following table shows the RLY OUT connector pin arrangement.
The following table provides the RLY OUT connector contact ratings.
( 2 ) RLY OUT Connection Cable
For the RLY OUT connection cable, use a cable of line size AWG28 to AWG14 (0.08 mm
2
to 1.5 mm
2
), maximum
sheath diameter
φ
3.4 mm.
The RLY OUT connector cable is similar in manufacture to the 24-VDC power supply cable.
Name
Connector
Name
Number
of Pins
Connector Model
Module Side
Cable Side
Manufacturer
RLY OUT
RLY OUT
2
734-162
734-YE102
Wago Corporation
Pin Number
Signal Name
Description
1
OUT
• Operating normally: Short-circuit
• Error occurred: Opened
2
OUT
Input Voltage
Current Capacity
24 VDC
0.5 A (resistance load)
0.25 A (induced load)
125 VAC
0.4A (resistance load)
0.2A (induced load)
RLY
OUT
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...