8.2 Troubleshooting
8.2.7 Troubleshooting Motion Errors
8-38
[ o ] Bit 12: Servo Driver Command Time-out Error
The above error occurs when Module allocations of SERVOPACK for MECHATROLINK communication have been
completed and the power is not being supplied to the SERVOPACK.
[ p ] Bit 13: Excessive ABS Encoder Rotations
[ q ] Bit 1E: Set Error Motor Type
[ r ] Bit 1F: Connected Encoder Type Error
Detection Timing
• Detected during execution of each motion commands.
• Detected by the MECHATROLINK communication control section when the Servo command responses
are checked for each process.
Processing when
Alarm Occurs
• The current command will be aborted.
Error and Cause
• The MECHATROLINK Servo command did not complete within the specified time (5 s).
Correction
• Check for alarms in the SERVOPACK for MECHATROLINK communication.
Detection Timing
• Enabled only when an absolute encoder is used for a finite length axis, and the electronic gear used.
Detected by the position management section when power is turned ON.
Processing when
Alarm Occurs
• The absolute position information read from the absolute encoder when the SEN signal turned ON is
ignored.
Error and Cause
• An operation error occurred when the absolute position information read from the absolute encoder is con-
verted from pulses to reference units at power ON.
Correction
• Check the gear ratio, number of encoder pulses for other motion fixed parameters.
Detection Timing
• Detected when the communication with the SERVOPACK is established.
Processing when
Alarm Occurs
• None
Error and Cause
• The motor type setting (rotary/linear) of the Machine Controller fixed parameter does not agree with that
of SERVOPACK parameter (Start Selection Pn000.3 for SGDH, Rotary/Linear for SGDS).
Correction
• Check the setting and model of the SERVOPACK.
Detection Timing
• Detected when the communication with the SERVOPACK is established.
Processing when
Alarm Occurs
• None
Error and Cause
• The motor type setting (rotary/linear) of the Machine Controller fixed parameter does not agree with the
motor type connected to the SERVOPACK.
Correction
• Check the motor.
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...