A-44
( d ) PARAMETER (parameter)
When RESULT(process result) = 4 (FMT_NG: parameter format error), an error code in the table below is output.
Otherwise, the connection number is output.
RESULT (process result)
Code (Hex)
Meaning
When RESULT
(process result) = 4
(FMT_NG: parameter format
error)
00
No error
01
Connection number is out of range
02
Time error for monitoring to receive MEMOBUS response
03
Error in setting retransmit count
04
Error in setting cyclic area
05
CPU number error
06
Data address error
07
Data size error
08
Function code error
Others
xx
Connection number