![YASKAWA JEPMC-MP2300S-E Скачать руководство пользователя страница 283](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300s-e/jepmc-mp2300s-e_user-manual_907071283.webp)
7.2 Requirements and Setting of Execution
7.2.1 Supported Version
7-3
7
Slave CPU Synchronous Function
7.2 Requirements and Setting of Execution
7.2.1 Supported Version
In order to use the slave CPU synchronous function, the master side must support the MP2300S.
The following table shows supported versions:
7.2.2 Requirements to Execute Slave CPU Synchronous Function
In order to use the slave CPU synchronous function, both master and slave sides must meet all the following require-
ments:
( 1 ) Master Side Requirements
• Supports the slave synchronous function (the versions mentioned above and later)
• H scan setting is either an integer multiple or an integer fraction of the MECHATROLINK communication cycle
• Communication system is MECHATROLINK-II (17Byte, 32Byte)
( 2 ) Slave Side Requirements
• Selects “Slave Synchronous Function = Enable” as a MECHATROLINK communication parameter
• H scan setting is either an integer multiple or an integer fraction of the MECHATROLINK communication cycle
setting
• H scan setting is either an integer multiple or an integer fraction of the master side H scan setting
• Sets “Resume Control of Slave Synchronization = OFF” as an output register assigned to MP2300S/SVB
( 3 ) Setting Example
• Master side
• Slave side
The master side H scan setting is an integral multiple of the MECHATROLINK communication cycle
The slave side H scan setting is an integer fraction of the master side H scan setting
The slave side H scan setting is an integral multiple of the communication cycle setting
→
If requirements are met, a slave CPU synchronization can be executed.
Controller
Model
Version
MP2100
JAPMC-MC2100(-E)
Ver.2.60 or later
MP2100M
JAPMC-MC2140(-E)
MP2300
JEPMC-MP2300(-E)
MP2300S
JEPMC-MP2300S-E
MP2400
JEPMC-MP2400-E
MP2000 series SVB-01
JAPMC-MC2310(-E)
Ver.1.21 or later
Communication cycle setting : 1 ms
H scan setting
: 4 ms
H scan setting
: 2 ms
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...