![YASKAWA JEPMC-MP2300S-E Скачать руководство пользователя страница 378](http://html.mh-extra.com/html/yaskawa/jepmc-mp2300s-e/jepmc-mp2300s-e_user-manual_907071378.webp)
A-24
OW
09
Motion Command
Control Flag
Bit 0: Holds a Command. (0: OFF/1: ON)
Yes
Yes
Bit 1: Interrupt a Command. (0: OFF/1: ON)
Yes
Yes
Bit 2: Moving Direction (JOG/ STEP)
(0: Forward rotation/1: Reverse rotation)
Yes
Yes
Bit 3: Zero Point Return Direction Selection
(0: Reverse rotation/1: Forward rotation)
Yes
Bit 4: Latch Zone Effective Selection (0: Disabled/1: Enabled)
Yes
Bit 5: Position Reference Type
(0: Incremental Addition Mode/1: Absolute Mode)
Yes
Yes
Bit 6: Phase Compensation Type
(0: Incremental Addition Mode/1: Absolute Mode)
Yes
Bits 7 to F: Reserved
OW
0A Motion Subcommand
0: NOP (No Command)
Yes
Yes
1: PRM_RD (Read User Constant)(Read SERVOPACK Parameter)
2: PRM_WR (Write User Constant)(Write SERVOPACK Parameter)
3: Reserved
4: SMON (Status Monitor)
Yes
5: FIXPRM_RD (Read Fixed Parameters)
Yes
Yes
OW
0B
−
Reserved
OL
0C
Torque/Thrust
Reference Setting
Unit is according to OW
03, bits 12 to 15 (Torque Unit).
Yes
Yes
OW
0E
Speed Limit Setting
at the Torque/Thrust
Reference
1 = 0.01% (percentage of rated speed)
Yes
OW
0F
−
Reserved
OL
10
Speed Reference
Setting
Unit is according to OW
03, bits 0 to 3 (Speed Unit).
Yes
Yes
OW
12
to
OW
13
−
Reserved
−
−
OL
14
Positive Side Limiting
Torque/Thrust
Setting at the Speed
Reference
Unit is according to OW
03, bits C to F (Torque Unit).
Yes
OL
16
Secondly Speed
Compensation
Unit is according to OW
03, bits 0 to 3 (Speed Unit).
Yes
Yes
OW
18 Override
1 = 0.01%
Yes
OW
19
to
OW
1B
−
Reserved
−
−
OL
1C
Position Reference
Setting
1 = 1 reference unit
Yes
Yes
OL
1E
Width of Positioning
Completion
1 = 1 reference unit
Yes
OL
20
NEAR Signal Output
Width
1 = 1 reference unit
Yes
OL
22
Error Count Alarm
Detection
1 = 1 reference unit
Yes
OL
24
−
Reserved for system use.
−
−
OW 26
Position Complete
Cheek Time
1 = 1 ms
Yes
OW
27
−
Reserved for system use.
OL
28
Phase Correction
Setting
1 = 1 reference unit
Yes
OL
2A
Latch Zone Lower
Limit Setting
1 = 1 reference unit
Yes
(cont’d)
Register No.
Name
Contents
SVB SVR
Содержание JEPMC-MP2300S-E
Страница 14: ...MEMO ...
Страница 24: ...MEMO ...
Страница 114: ...MEMO ...
Страница 132: ...MEMO ...
Страница 154: ...5 2 User Programs 5 2 2 Motion Programs 5 22 2 Example using a ladder program ...
Страница 156: ...5 2 User Programs 5 2 2 Motion Programs 5 24 2 Example using a ladder program ...
Страница 190: ...MEMO ...
Страница 280: ...MEMO ...
Страница 300: ...7 3 Operation 7 3 5 How to Determine Input Error 7 20 Continued from the previous page ...
Страница 302: ...7 3 Operation 7 3 5 How to Determine Input Error 7 22 Application Example Continued on the next page ...
Страница 306: ...7 3 Operation 7 3 6 Management to Resume Slave CPU Synchronization 7 26 Application Example Continued on the next page ...
Страница 310: ...MEMO ...