![YASKAWA FSDrive-MV1S Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/yaskawa/fsdrive-mv1s/fsdrive-mv1s_instructions-manual_3478741097.webp)
5
-32
Multi-function Analog Input Functions
Note Set to 0F when the analog input is used for the built-in PLC or not used as multi-function contact input.
Setting
Value
Function
Contents (100%)
Control Methods
Open-
loop
Vector
Flux
Vector
00
Auxiliary frequency reference (Can be set
only for H3-09)
Maximum number of rotations
Yes
Yes
01
Frequency gain
Frequency reference command value
Yes
Yes
02
Frequency bias
Maximum number of rotations
Yes
Yes
05
Accel/decel time changes (reduction
coefficient)
Set acceleration and deceleration times
Yes
Yes
06
DC injection braking current
Inverter rated current
Yes
No
07
Overtorque detection level
Motor rated torque
Yes
Yes
09
Frequency reference lower limit level
Maximum number of rotations
Yes
Yes
0A
Jump frequency
Maximum number of rotations
Yes
Yes
0F
Not used (Set when the terminal is used
for the built-in PLC or not used)
−
Yes
Yes
10
Positive torque limit
Motor rated torque
Yes
Yes
11
Negative torque limit
Motor rated torque
Yes
Yes
12
Regenerative torque limit
Motor rated torque
Yes
Yes
13
Torque reference at torque control/Torque
limit at speed control
Motor rated torque
No
Yes
14
Torque compensation
Motor rated torque
No
Yes
15
Positive/negative torque limit
Motor rated torque
Yes
Yes
1F
(For H3-09 and H3-13) Analog input not
used
−
Yes
Yes
(For H3-05) Frequency reference