5
-56
U1-83
Error status 4
Inverter error status 4.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
−
[Bit]
A
A
92H
Error Sts 4
U1-84
Error status 5
Inverter error status 5.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
−
[Bit]
A
A
93H
Error Sts 5
U1-86
AO1 output
value
Monitors the AO1 output value.
-10 to 10[V]: -32768 to 32767
32767
−
A
A
95H
AO1 output
value
Constant
Number
Name
Description
100% Value
Min.
Unit
Control
Methods
MEMOBUS
Register
Display
Open-
loop
Vector
Flux
Vector
1: Cell fault (CFA)
1: Link error between CCB
and MB. (LIN)
1: Parity error between CCB
and MB. (PAR)
1: Hard error (HDE)
1: Output ground fault (OGF)
1: Inverter output overcurrent
(IOC)
1: Cell overheating (TMP)
1: CPU error (CER)
0
0 0
0
0
0 0
0
Not Used
1: Modurator watchdog
timer fault (DTM)
Not Used
Not Used
Not Used
1: Control power supply
error (CUV)
Not Used
1: Power supply error for
analog circuit. (CTF)
0
0 0
0
0
0 0
0
1: Cooling fan fault 1 (FAN1)
1: Cooling fan fault 2 (FAN2)
1: Cooling fan fault 3 (FAN3)
1: Cooling fan fault 4 (FAN4)
1: Transformer temperature
fault (TME)
1: Custom fault 4 input 1 (FLT1)
1: Custom fault 4 input 2 (FLT2)
1: Custom fault 4 input 3 (FLT3)
0
0 0
0
0
0 0
0
1: Custom fault 4 input (FLT4)
1: Custom fault 5 input (FLT5)
1: Custom fault 6 input (FLT6)
1: Custom fault 7 input (FLT7)
1: Custom fault 8 input (FLT8)
1: Custom alarm 1 input (ALM1)
1: Custom alarm 2 input (ALM2)
1: Custom alarm 3 input (ALM3)
0
0 0
0
0
0 0