6
-50
Speed reference limit (Setting: 31)
Off
Other than on condition
On
Enables the speed reference limit in the following conditions (During flux vector control method):
1. Frequency reference
≥
Frequency reference upper limit (d2-01)
Frequency reference
≤
Frequency reference lower limit (d2-02)
Frequency reference
≥
Output frequency lower limit of the multi-function analog input
(Setting: 9)
2. The frequency reference is less than the Min. output frequency (E1-09), and b1-05 is set to 1,
2, or 3.