YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
29
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
B004
3.5
2
14
17
31
B006
6.0
2
17
26
43
B010
9.6
2
36
50
86
B012
12.2
2
48
60
108
Table 7.12 Three-Phase 200 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
2001
1.2
2
7
5
12
2002
1.9
2
9
9
18
2004
3.5
2
11
16
27
2006
6
2
14
25
39
2010
9.6
2
25
51
76
2012
12.2
2
30
61
91
2021
21
2
52
111
163
2030
30
2
59
175
234
2042
42
2
101
250
351
2056
56
2
127
357
484
2070
70
2
202
455
657
Table 7.13 Three-Phase 400 V Class (Finless-Type Drive)
Drive Model
Rated Output
Current
(A)
Carrier
Frequency
(kHz)
Drive Watt Loss (W)
Interior Unit
Loss
Heatsink Plate Loss
(P
Loss
)
Total
Loss
4001
1.2
2
8
7
15
4002
2.1
2
13
12
25
4004
4.1
2
14
24
38