182
YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
Model
Terminal
Recomm.
Gauge
mm
2
Applicable
Gauge
mm
2
Wire
Stripping
Length
mm
Terminal
Screw
Size and
Shape
Tightening
Torque
N
∙
m (lbf
∙
in)
2056
R/L1, S/L2, T/L3
16
4 - 25
18
M5
2.3 - 2.5
(19.8 - 22)
U/T1, V/T2, W/T3
16
4 - 25
18
M5
2.3 - 2.5
(19.8 - 22)
-, +1, +2
25
6 - 35
18
M5
•
≦
25 mm
2
2.3 - 2.5
(19.8 - 22)
•
35 mm
2
≦
4.1 - 4.5
(36 - 40)
B1, B2
10
4 - 16
10
M4
1.5 - 1.7
(13.5 - 15)
10
10 - 25
-
M6
5.4 - 6.0
(47.8 - 53.1)
2070
R/L1, S/L2, T/L3
25
6 - 35
20
M6
5 - 5.5
(
45 - 49)
U/T1, V/T2, W/T3
16
6 - 25
20
M6
5 - 5.5
(
45 - 49)
-, +1, +2
35
10 - 50
20
M6
5 - 5.5
(
45 - 49)
B1, B2
10
4 - 16
10
M4
1.5 - 1.7
(13.5 - 15)
16
10 - 25
-
M6
5.4 - 6.0
(47.8 - 53.1)
*1