YASKAWA
TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
19
■
Rated Output Current
, and
give the rated output current values.
Note:
•
Rated output current values are applicable for drives that operate at standard specifications.
•
Derate the output current in applications that:
–
Increase the carrier frequency
–
Have high ambient temperature
•
Use
C6-01 [Normal / Heavy Duty Selection]
to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Table 6.2 Single-Phase AC 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
B001
0.1 (1/6)
0.8
0.2 (1/6)
1.2
B002
0.2 (1/4)
1.6
0.4 (1/4)
1.9
B004
0.4 (1/2)
3.0
0.75 (3/4)
3.5
B006
0.75 (1)
5.0
1.1 (1.5)
6.0
B010
1.5 (2)
8.0
2.2 (3)
9.6
B012
2.2 (3)
11.0
3.0 (3)
12.2
Table 6.3 Three-Phase AC 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
Maximum
Applicable Motor
Output
kW (HP)
Rated Output
Current
A
2001
0.1 (1/6)
0.8
0.2 (1/6)
1.2
2002
0.2 (1/4)
1.6
0.4 (1/4)
1.9
2004
0.4 (1/2)
3.0
0.75 (3/4)
3.5
2006
0.75 (1)
5.0
1.1 (1.5)
6.0
2010
1.5 (2)
8.0
2.2 (3)
9.6