Overview
Finless-type drives do not have cooling fins, which are the main heat-generating
component of the drive. The finless-type drive uses the enclosure panel (metal plate) as a
cooling fin to release the heat generated by the drive. This will let you install the drive in
a smaller enclosure panel.
Finless-type drives are recognized components by UL (Underwriters Laboratories Inc.).
Machines and devices integrated with this product must satisfy
conditions for compliance with UL standards.
4
Drive Specifications
Note:
•
To get the OLV specifications, do Rotational Auto-Tuning.
•
To get the longest product life, install the drive in an environment that meets the necessary specifications.
Table 4.1 Environment
Item
Specification
Area of Use
Indoors, inside enclosure panel
Power Supply
Overvoltage Category III (IEC60664)
Ambient
Temperature
Setting
-10 °C to +35 °C (14 °F to 95 °F)
•
Drive reliability is better in environments where the temperature does not increase or
decrease quickly.
•
When you install the drive in an enclosure, use a cooling fan or air conditioner to keep the
internal air temperature in the permitted range.
•
Do not let the drive freeze.
•
You can use finless-type drives at a maximum of +50 °C (122 °F) when you derate the output
current.
Humidity
95% RH or less
Do not let condensation form on the drive.
Storage
Temperature
-20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Surrounding
Area
Pollution degree 2 or less (IEC 60664-1)
Install the drive in an area without:
•
Oil mist, corrosive or flammable gas, or dust
•
Metal powder, oil, water, or other unwanted materials
•
Radioactive or flammable materials
•
Harmful gas or fluids
•
Salt
•
Direct sunlight
Keep wood and other flammable materials away from the drive.