Register No.
Contents
00C3H
Fault contents 6
bit 0 to 4
Reserved
bit 5
Output Current Imbalance (LF2)
bit 6
Pullout Detection (STo)
bit 7
PG Disconnected (PGo)
bit 8
MECHATROLINK Watchdog Timer Error (E5)
bit 9
Reserved
bit A
Too many speed search restarts (SEr)
bit B to F
Reserved
00C4H
Fault contents 7
bit 0
PID Feedback Loss (FbH)
bit 1
External Fault 1, input terminal S1 (EF1)
bit 2
External Fault 2, input terminal S2 (EF2)
bit 3
Mechanical Weakening Detection 1 (oL5)
bit 4
Mechanical Weakening Detection 2 (UL5)
bit 5
Current Offset Fault (CoF)
bit 6
Reserved
bit 7
Reserved
bit 8
DriveWorksEZ fault (dWFL)
bit 9 to F
Reserved
00C8H
Alarm contents 2
bit 0
Undervoltage (Uv)
bit 1
Overvoltage (ov)
bit 2
Heatsink Overheat (oH)
bit 3
Drive Overheat (oH2)
bit 4
Overtorque 1 (oL3)
bit 5
Overtorque 2 (oL4)
bit 6
Run Commands Input Error (EF)
bit 7
Drive Baseblock (bb)
bit 8
External Fault 3, input terminal S3 (EF3)
bit 9
External Fault 4, input terminal S4 (EF4)
bit A
External Fault 5, input terminal S5 (EF5)
bit B
External Fault 6, input terminal S6 (EF6)
bit C
External Fault 7, input terminal S7 (EF7)
bit D, E
Reserved
bit F
Overspeed (oS)
C.10 MEMOBUS/Modbus Data Table
454
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual