No.
Description
Unit
Default Settings
−
Model
−
2A0012
2A0020
2A0030
o2-04
Drive Model Selection
Hex
66
68
6A
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
E2-11
(E4-11,
T1-02)
Motor rated power
kW
2.2
3.0
3.7
5.5
5.5
7.5
b3-06
Speed Search current 1
−
0.5
0.5
0.5
0.5
0.5
0.5
b3-08
Current Control Gain during Speed
Search (Speed Estimation Type)
–
0.5
0.5
0.5
0.5
0.5
0.5
b8-04
Energy saving coefficient
−
156.8
136.4
122.9
94.8
94.75
72.69
C6-02
Carrier frequency
−
3
7
3
7
3
7
E2-01
(E4-01,
T1-04)
Motor rated current
A
8.5
11.4
14
19.6
19.6
26.6
E2-02
(E4-02)
Motor rated slip
Hz
2.9
2.7
2.73
1.5
1.5
1.3
E2-03
(E4-03)
Motor no-load current
A
3.0
3.7
4.5
5.1
5.1
8.0
E2-05
(E4-05)
Motor line-to-line resistance
Ω
1.601
1.034
0.771
0.399
0.399
0.288
E2-06
(E4-06)
Motor leakage inductance
%
18.4
19
19.6
18.2
18.2
15.5
E2-10
(E4-10)
Motor Iron Loss
W
77
91
112
172
172
262
E5-01
Motor Code
hex
0006
0006
0008
0008
FFFF
FFFF
L2-02
Momentary power loss ride-
through time
s
0.5
0.5
1
1
1.0
1.0
L2-03
Momentary power loss Baseblock
time
s
0.5
0.5
0.6
0.7
0.7
0.8
L2-04
Momentary power loss voltage
recovery time
s
0.3
0.3
0.3
0.6
0.3
0.6
L2-05
Uv detection voltage
V dc
190
190
190
190
190
190
L3-24
Motor acceleration time
s
0.145
0.145
0.154
0.168
0.168
0.175
L8-02
Overheat alarm level
°C
100
100
110
110
115
115
L8-09
Ground fault selection
−
0
0
0
0
1
1
L8-38
Carrier frequency reduction
selection
−
1
1
1
1
2
2
n1-03
Hunting Prevention Time Constant
ms
10
10
10
10
10
10
n2-01
Speed Feedback Detection Control
(AFR) Gain
–
1.00
1.00
1.00
1.00
1.50
1.50
B.5 Defaults by Drive Model and Duty Rating (ND/HD)
412
YASKAWA ELECTRIC SIEP C710606 18F YASKAWA AC Drive – V1000 Technical Manual