3 - 36
INSP
ADJ
NOTE:
Since MF batteries are sealed, it is not possi-
ble to check the charge state of the battery by
measuring the specific gravity of the electro-
lyte. Therefore, the charge of the battery has
to be checked by measuring the voltage at the
battery terminals.
1. Remove:
●
Battery cover
2. Disconnect:
●
Battery leads
(from the battery terminals)
CAUTION:
First, disconnect the negative battery lead
1
, and then the positive battery lead
2
.
3. Remove:
●
Battery
4. Measure:
●
Battery charge
Measurement steps:
●
Connect a pocket tester
1
to the battery
terminals.
Tester positive probe
→
battery positive terminal
Tester negative probe
→
battery negative terminal
NOTE:
●
The charge state of an MF battery can be
checked by measuring its open-circuit
voltage (i.e., the voltage when the positive
terminal is disconnected).
●
No charging is necessary when the open-
circuit voltage equals or exceeds 12.8 V.
2
1
BATTERY INSPECTION AND CHARGING
(TT-R125E/TT-R125LWE)
Содержание TT-R125(W) 2006
Страница 22: ...INDEX GENERAL INFORMATION SPECIFICATIONS REGULAR INSPECTION AND ADJUSTMENTS ENGINE CHASSIS ELECTRICAL...
Страница 49: ...GEN INFO MEMO...
Страница 185: ...INSP ADJ MEMO...
Страница 256: ...3 39 INSP ADJ Charging method using a variable voltage charger BATTERY INSPECTION AND CHARGING TT R125E TT R125LWE...
Страница 257: ...3 40 INSP ADJ Charging method using a constant voltage charger BATTERY INSPECTION AND CHARGING TT R125E TT R125LWE...
Страница 310: ...4 23 ENG CAMSHAFT AND ROCKER ARMS 5 Install Camshaft bearing holder 1 Bolt 2 T R 10 Nm 1 0 m kg 7 2 ft lb LT...
Страница 577: ...ELEC MEMO...
Страница 591: ...ELEC MEMO...
Страница 611: ...ELEC MEMO...
Страница 614: ......
Страница 615: ......