114. MAIN FIX 1.8 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 160 m amateur band.
Available Values
: 1800 - 1999 kHz (1 kHz steps)
Default Setting
: 1800 kHz
115. MAIN FIX 3.5 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 80 m amateur band.
Available Values
: 3500 - 3999 kHz (1 kHz steps)
Default Setting
: 3500 kHz
116. MAIN FIX 5.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 60 m amateur band.
Available Values
: 5250 - 5499 kHz (1 kHz steps)
Default Setting
: 5250 kHz
117. MAIN FIX 7.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 40 m amateur band.
Available Values
: 7000 - 7299 kHz (1 kHz steps)
Default Setting
: 7000 kHz
118. MAIN FIX 10 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 30 m amateur band.
Available Values
: 10100 - 10149 kHz (1 kHz steps)
Default Setting
: 10100 kHz
119. MAIN FIX 14 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 20 m amateur band.
Available Values
: 14000 - 14349 kHz (1 kHz steps)
Default Setting
: 14000 kHz
120. MAIN FIX 18 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 17 m amateur band.
Available Values
: 18000 - 18199 kHz (1 kHz steps)
Default Setting
: 18068 kHz
121. MAIN FIX 21 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 15 m amateur band.
Available Values
: 21000 - 21449 kHz (1 kHz steps)
Default Setting
: 21000 kHz
122. MAIN FIX 24 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 12 m amateur band.
Available Values
: 24800 - 24989 kHz (1 kHz steps)
Default Setting
: 24890 kHz
123. MAIN FIX 28 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 10 m amateur band.
Available Values
: 28000 - 29699 kHz (1 kHz steps)
Default Setting
: 28000 kHz
124. MAIN FIX 50 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Main
band (VFO-A) 6 m amateur band.
Available Values
: 50000 - 53999 MHz (1 kHz steps)
Default Setting
: 50000 kHz
125. SUB FIX 1.8 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 160 m amateur band.
Available Values
: 1800 - 1999 kHz (1 kHz steps)
Default Setting
: 1800 kHz
126. SUB FIX 3.5 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 80 m amateur band.
Available Values
: 3500 - 3999 kHz (1 kHz steps)
Default Setting
: 3500 kHz
127. SUB FIX 5.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 60 m amateur band.
Available Values
: 5250 - 5499 kHz (1 kHz steps)
Default Setting
: 5250 kHz
128. SUB FIX 7.0 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 40 m amateur band.
Available Values
: 7000 - 7299 kHz (1 kHz steps)
Default Setting
: 7000 kHz
129. SUB FIX 10 MHz
Function
: Selects the scan start frequency of the FIX
mode Spectrum Scope while monitoring on the Sub
band (VFO-B) 30 m amateur band.
Available Values
: 10100 - 10149 kHz (1 kHz steps)
Default Setting
: 10100 kHz
Содержание FTDX-9000MP
Страница 1: ...FTDX 9000MP Operation Manual...
Страница 2: ......
Страница 125: ...Page 123 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 166: ...Page 164 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 171: ...Page 169 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 175: ...Page 173 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 178: ...Page 176 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...