106
1. The parameter range is 0000-0014, which is allocated to other input terminals through parameter P5-24.
2. When an alarm occurs, find out the cause of the alarm and remove it, then clear the alarm by setting the
signal to be effective.
3. /ALM-RST signal can be assigned to other terminals through this parameter, because the alarm signal is
related to the safe operation of the servo, so the /ALM-RST signal can not be set to be always valid
(n.0010).
4.8.6.3 Other SI terminal function
Terminal name
Description
Chapter
/S-ON
Servo enable
5.2.2
/P-OT
No forward driving
5.2.4
/N-OT
No reverse driving
/P-CL
Forward side external torque limit
/N-CL
Reverse side external torque limit
/SPD-D
Internal speed direction
/SPD-A
Internal setting speed
Position mode reference origin triggering
/SPD-B
Internal setting speed
Position mode reference origin triggering
/C-SEL
Control mode selection
5.1.2
/ZCLAMP
Zero clamp
/INHIBIT
Command pulse inhibit
5.3.3.4
Содержание DF3E Series
Страница 1: ... 1 DF3E series servo driver User manual Wuxi Xinje Electric Co Ltd Data No SF3 01 20210607 1 0 ...
Страница 23: ...15 Fixed installation Bending radius 5 D 5 D Note D represents the finished product cable diameter ...
Страница 121: ...113 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 126: ...118 4 click ok to estimate the inertia 5 set the auto tuning parameters ...
Страница 128: ...120 7 Wait for the end of the auto tuning ...
Страница 132: ...124 8 The upper device starts to send pulses wait the completion of auto tuning 9 Auto tuning is finished click ok ...
Страница 184: ...176 Appendix 8 Torque speed characteristic curve ...