26
Mode
Forward running
Reverse running
P0-05 setting
Standard setting
CCW is forward
run
P0-05=0
Reverse mode
CW is forward
run
P0-05=1
4.2.4 Stop mode
Servo shutdown can be divided into inertia shutdown and deceleration shutdown according to the shutdown mode.
The following explains the servo shutdown mode.
Shutdown
mode
Inertia stop
Deceleration stop
Stopping
principle
The servo driver is not enabled, the servo motor is
not powered, and free deceleration to 0. The
deceleration time is affected by mechanical inertia,
equipment friction, etc.
The servo driver outputs the
reverse braking torque, and the
motor decelerates rapidly to 0.
Stopping
features
Advantages:
smooth
deceleration,
small
mechanical impact, small mechanical impact
Disadvantage: slow deceleration process
Advantages: short deceleration
time
Disadvantages:
mechanical
impact
According to different scenarios of servo shutdown, it can be divided into servo off shutdown, alarm shutdown
and over travel shutdown.
(1) Servo OFF and alarm shutdown
◼
Related parameter
Parameter
Meaning
Default
setting
Unit
Range
Modify
Effective
P0-30
Stop timeout
20000
1ms
0~65535
Servo bb
At once
P3-32
braking torque
300
1%
0~1000
Anytime
At once
P5-03
Rotation detection
speed
50
rpm
0~10000
Anytime
At once
P0-27
Servo OFF stop mode
0
-
0/2
Servo bb
At once
P0-29
Alarm stop mode
2
-
0/2
Servo bb
At once
P0-31
Deceleration stop
time
25
1ms
0~5000
Servo bb
At once
Parameter
Value
Meaning
P0-27/
P0-29
0
inertia stop and maintain the inertia operation state after stop.
2
deceleration brake stop and maintain the inertia operation state after
stop.
Note:
(1) P0-27 / P0-29 = 0, inertia stops, and maintains inertia operation state after stopping.
When the servo is off and the alarm occurs, the motor starts to stop by inertia until the speed is less than P5-03,
and then it turns to free stop. The servo will time the inertia stop process. In the process of inertia stop, if the
timing time has been greater than P0-30, and the motor speed has not dropped below P5-03, the servo will directly
free stop, and give the stop timeout alarm E-262.
(2) P0-27 / P0-29 = 2, deceleration braking stops, and maintains inertia operation state after stopping.
When servo off and alarm occur, the motor will generate a braking torque of P3-32. The motor will start braking
and stop until the speed is less than P5-03 (rotation detection speed), and then it will turn to free stop. At the same
time, the servo will timing the braking stop process. In the process of inertia stop, if the timing time has been
greater than P0-30, and the motor speed has not dropped below P5-03, the servo will directly free stop, and give
the stop timeout alarm E-262.
(3) The so terminal of servo driver is equipped with holding brake function. No matter P0-27 / P0-29 = 0 or 2, it
CCW
CW
CW
CCW
Содержание DF3E Series
Страница 1: ... 1 DF3E series servo driver User manual Wuxi Xinje Electric Co Ltd Data No SF3 01 20210607 1 0 ...
Страница 23: ...15 Fixed installation Bending radius 5 D 5 D Note D represents the finished product cable diameter ...
Страница 121: ...113 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 126: ...118 4 click ok to estimate the inertia 5 set the auto tuning parameters ...
Страница 128: ...120 7 Wait for the end of the auto tuning ...
Страница 132: ...124 8 The upper device starts to send pulses wait the completion of auto tuning 9 Auto tuning is finished click ok ...
Страница 184: ...176 Appendix 8 Torque speed characteristic curve ...