73
The PDS status after stop is Operation enabled.
5.
Fault reaction option code (605Eh)
Set the motor stop method when the alarm occurs.
Index
Sub-
Index
Name/Description
Range
Date
Type
Access
PDO
Op-
mode
605Eh
00h
Fault reaction option code
0-2
I16
rw
NO
All
Set the time sequence when the alarm occurs. It is different according to the
definition of control mode.
The setting is prohibited except the following values.
Value
Definition
0
Stop at once, PDS status migrates to Fault.
1
The control mode is PP, PV: motor stop through 0x6084 (Profile
deceleration), PDS status migrates to Fault.
The control mode is HM: motor stop through 0x609Ah (Homing
acceleration), PDS status migrates to Fault.
The control mode is TQ: motor stop through 0x6087 (Torque Slope),
PDS status migrates to Fault.
2
The control mode is PP, PV, HM: motor stop through 6085h (Quick
stop deceleration), PDS status migrates to Fault.
The control mode is TQ: motor stop through 0x6087 (Torque Slope),
PDS status migrates to Fault.
Examples of deceleration stop action when alarm occurs:
It will start to decelerate and stop when the alarm occurs.
PDS status during deceleration is Fault reaction active.
The PDS status after stop is Fault.
Содержание DF3E Series
Страница 1: ... 1 DF3E series servo driver User manual Wuxi Xinje Electric Co Ltd Data No SF3 01 20210607 1 0 ...
Страница 23: ...15 Fixed installation Bending radius 5 D 5 D Note D represents the finished product cable diameter ...
Страница 121: ...113 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 126: ...118 4 click ok to estimate the inertia 5 set the auto tuning parameters ...
Страница 128: ...120 7 Wait for the end of the auto tuning ...
Страница 132: ...124 8 The upper device starts to send pulses wait the completion of auto tuning 9 Auto tuning is finished click ok ...
Страница 184: ...176 Appendix 8 Torque speed characteristic curve ...