145
Main
type
Sub
type
Code
Description
Reasons
Solutions
31
5
E-315
When
the
motor code is
read
automatically,
the
motor
parameter is 0
Read the motor code
is 0
On the premise that the driver and
motor are matched and can be used
together, read the alarm shielding
position of motor parameters through
P0-53, and set the motor code
correctly
6
E-316
Auto-read
code error
The auto read motor
code is inconsistent
with the motor code
set in P0-33
Check U3-00 and motor label.
①
If the two values are the same,
change P0-33 motor code or set P0-33
to 0 to read motor code automatically;
②
If the two values are different,
contact the manufacturer for technical
support
85
2
E-852
Interruption of
data
interaction
with
CANopen
master station
Communication
interruption
between
master
and
slave
station
①
Check whether the CAN network
wiring is disconnected or damaged;
②
Check whether the CANopen master
station is powered down;
③
After ensuring that there is no
problem with the wiring, first power off
and restart CANopen slave station, and
then power off and restart CANopen
master station.
Содержание DF3E Series
Страница 1: ... 1 DF3E series servo driver User manual Wuxi Xinje Electric Co Ltd Data No SF3 01 20210607 1 0 ...
Страница 23: ...15 Fixed installation Bending radius 5 D 5 D Note D represents the finished product cable diameter ...
Страница 121: ...113 2 select jog setting or manual setting to configure the inertia estimation trip 3 Set the auto tuning interface ...
Страница 126: ...118 4 click ok to estimate the inertia 5 set the auto tuning parameters ...
Страница 128: ...120 7 Wait for the end of the auto tuning ...
Страница 132: ...124 8 The upper device starts to send pulses wait the completion of auto tuning 9 Auto tuning is finished click ok ...
Страница 184: ...176 Appendix 8 Torque speed characteristic curve ...