Installation Procedure
Accuset Final Installation
Installation Procedure
AS00doc032519
1-35
1
13.
Install the Accuset control to the top of the sawmill control box.
Insert the Accuset control panel under the L-shaped bar clamp and slide forward into
place. The four holes in the front of the Accuset control panel should align with the four
holes in the top of the sawmill control box. Tighten the bar clamp mounting screws to
secure the back of the Accuset control panel to the sawmill control box. Use the four
existing #10-24 x 3/8” self-tapping screws (removed when original cover was removed) to
secure the front of the Accuset control panel to the sawmill control box.
See Figure 1-29.
14.
Plug the cable from the transducer sensor into the connector in the back of the Accuset
control box. Route the cable along the back side of the control pedestal and secure with
the three 10” tie wraps provided.
15.
Reconnect the negative battery lead and replace the battery box cover.
FIG. 1-29
3H0834-1
Existing
Screws (4)
Accuset
Control
(Cover not shown)
Transducer Sensor
Cable Plug