Accuset Troubleshooting
Sensor LED Lights (Rev. D.02 - E.02 only)
3
3-14
AS00doc032519
Accuset Troubleshooting
3.5
Sensor LED Lights (Rev. D.02 - E.02 only)
See Figure 3-6.
The manufacturer’s instructions for troubleshooting the sensor LED
lights is provided below.
FIG. 3-6
The G-Series simple visual user interface helps resolve the majority of cus-
tomer installation and troubleshooting issues. Integrated LEDs indicate
(refer to LED indicator table):
G
Normal operating conditions
G
Error conditions, power and sensor/control interface issues
G
Programming modes (IR or hard wired)
Hard-wired G-Series serial communication enables diagnostic feedback at a
convenient remote location. Access to internal sensor conditions minimizes
troubleshooting efforts and enables the development of more sophisticated
controller diagnostic routines. All of these features will simplify sensor
installation and maximize operational productivity.
Green
Red
Description
OFF
OFF
No power to sensor
OFF
ON
Self-diagnostic error
OFF
FLASHING
IR programming mode
ON
OFF
Normal sensor function
ON
ON
Magnet not detected
ON
FLASHING
Missing (external) interrogation
FLASHING
OFF
Serial programming mode
FLASHING
ON
Magnet signal weak
FLASHING
FLASHING
Power out of range (high or low)
G-Series electronics housing with built-in LEDs
G-Series LED indicator table