![Wood-mizer Accuset Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/wood-mizer/accuset/accuset_safety-operation-maintenance-and-parts-manual_994535011.webp)
Installation Procedure
Sensor Installation (Rev. A.01+)
Installation Procedure
AS00doc032519
1-7
1
5.
Install the sensor magnet mount block to the scale mount bracket using the four provided
#10-24 x 1/2" hex head bolts and flat washers. Check the area between the bracket and
block. If there is a gap, use the provided extra #10 washers as necessary to fill the gap.
This will prevent bending of the scale bracket when the mounting bolts are tightened.
6.
Position the magnet assembly so the holes in the magnet mounting bracket align with the
holes in the magnet mount block.
7.
Secure the magnet assembly to the mount block with the provided 1/4-20 x 3/4” hex head
bolts and flat washers. Adjust the assembly in the slotted holes so the magnet is centered
around the sensor rod.
See Figure 1-6.
FIG. 1-6
3H0817-5
#10-24 x 1/2”
Hex Head Bolt (4)
#10 SAE Flat
Washer (4)
Magnet
Assembly
Scale Mount
Bracket
Use extra #10 washers
as necessary to fill gap
between scale bracket and
magnet mount block
1/4-20 x 3/4”
Hex Head Bolt (2)
1/4” SAE Flat
Washer (2)
Magnet Mount Block