![Wood-mizer Accuset Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/wood-mizer/accuset/accuset_safety-operation-maintenance-and-parts-manual_994535027.webp)
Installation Procedure
Wiring Installation for Super Sawmills
Installation Procedure
AS00doc032519
1-23
1
See Figure 1-20.
There are two red 12VDC wires provided. Only one of these wires will
be used, depending upon your mill model. Both wires have a 1/4” ring terminal connected
to one end. For Super model sawmills, use the wire with the 5/16” ring terminal on the
other end of the wire.
3.
Install the red 12VDC wire to terminal 3 of Solenoid 4 or 5. For best results, install to sole-
noid terminal with only one pre-existing connection. Be sure to leave the pre-existing con-
nection in place. To install, remove the 5/16” hex nut and lock washer from solenoid
terminal, install ring terminal to solenoid terminal, and replace lock washer and hex nut.
Tighten to secure. Reinstall the side panel to the sawmill control box.
See Figure 1-21.
FIG. 1-20
FIG. 1-21
3H0568-1
5/16" Ring
(Super Models)
#10 Fork
(Standard Models)
3H0849-8
Solenoid 5, Terminal 3
Solenoid 4, Terminal 3