Installation Procedure
Accuset Final Installation
Installation Procedure
AS00doc032519
1-31
1
9.
Connect the MOTOR, GND and 12VDC wires from the sawmill control box to the Accuset
circuit board as shown below.
10.
Install the provided 8” conduit to the wires connecting the Accuset control to the sawmill
control. Position the conduit about 3” - 4” inches from the wire terminals connected to the
Accuset control. Secure each end of the conduit with two of the provided 6” tie wraps.
Wire
Connection
(Super Model
Sawmills)
Connection
(Standard Model
Sawmills)
Connection Type
Red DRUM DN
Up/Dn Drum
Switch TRM 4
Up/Dn Drum
Switch TRM 4
Fork Terminal
Black DRUM UP
Up/Dn Drum
Switch TRM 1
Up/Dn Drum
Switch TRM 1
Fork Terminal
Red Pwr Filter
1
1
Power Filter added Accuset Rev. C.00
Circuit Breaker
CB4 ‘BAT’
Circuit Breaker
CB4 ‘BAT’
Ring Terminal
Red Trans. Pwr
2
2
Transducer Power Adaptor added Accuset Rev. D.02 - E.02
Circuit Breaker
CB4 ‘BAT’
Circuit Breaker
CB4 ‘BAT’
Ring Terminal
Red MOTOR
MOTR Accuset
Terminal
MOTL Accuset
Terminal
Threaded Stud (Tighten lock nut to 85 in-lbs.)
Black MOTOR
MOTL Accuset
Terminal
MOTR Accuset
Terminal
Threaded Stud (Tighten lock nut to 85 in-lbs.)
Black GND
GND
GND
Threaded Stud (Tighten lock nut to 85 in-lbs.)
Red 12VDC
12VDC
12VDC
Threaded Stud (Tighten lock nut to 85 in-lbs.)
FIG. 1-28 SUPER MODELS ONLY (ACCUSET REV. C.00 - D.01, E.03+)
MOTR
MOTL
GND
+12V
Bl
k Mot
o
r
Re
d Mo
to
r
Re
d 1
2V
D
C
Blk
Gr
ou
nd
3H0850-3B
NOTE:
Only wires for field
installation are shown. Leave
all other wires connected as is.
Blk Drum Up
Red Drum Dn
Up/Dn Drum Switch TRM 1
Up/Dn Drum Switch TRM 4
SUPER Models Only
Circuit Breaker
CB4 ‘BAT’
R
ed
P
ow
er
F
ilt
er