Accuset Troubleshooting
Common Problems
Accuset Troubleshooting
AS00doc032519
3-1
3
SECTION 3 ACCUSET TROUBLESHOOTING
STOP!
Be sure you have performed the preliminary trouble-
shooting procedure before troubleshooting a specific elec-
trical system. This will save you alot of time wasted
troubleshooting the wrong system! Also, when calling Cus-
tomer Service for assistance, you will be required to use a
digital voltmeter.
Before troubleshooting the Accuset, first be sure all components are properly installed.
This is especially important if you have recently replaced a component. Recheck that the
component is properly installed and connected. If any maintenance procedures that might
affect Accuset performance were performed immediately before a problem developed,
check that the procedures were performed properly. Adjustments to the up/down chain,
vertical mast slide pads and up/down drive belt may affect Accuset performance. Sawmill
components such as covers and guards that might interfere with Accuset wiring should
also be checked.
This troubleshooting section was developed assuming you have isolated the problem to
the Accuset option. Problems with the sawmill battery/charging system, circuit breakers,
solenoids and up/down system can affect the Accuset option. Refer to the sawmill trou-
bleshooting information to solve problems with these components. A list of common
Accuset problems is provided below.
Accuset Rev. D.02 and later:
The transducer sensor is equipped with LED lights to help
diagnose problems with the sensor.
See Section 3.5 Sensor LED Lights (Rev. D.02 - E.02
3.1
Common Problems
1
Accuset display has no backlight.
Most commonly happens when Accuset is not pow-
ered.
See Section 3.2 Accuset Display Problems
.
2
Accuset display has a back light but no readout.
Most commonly happens when the
LCD contrast is not adjusted properly or the transducer is not providing a proper value.
Check the display contrast.
Adjust the display contrast if necessary (
See Section 2.1.1 Contrast Adjustment
of the
Accuset manual for instructions). If it is not possible to adjust the display contrast, check
the transducer connections. If the transducer connections are good, call Customer Ser-
vice for assistance.
3
Accuset display shows two horizontal lines (Rev. A.00 - A.03 only).
This problem can