27
2.
For the installer
– Route both cables from the air control upwards in the side panels via the cable channel feed-through into the control
panel as shown in Fig. 54 and connect as shown in Fig. 55.
– Route the lambda sensor cable downwards from the control panel via the cable channel feed-through in the side
panel and connect to the lambda sensor – Fig. 54.
Fig. 54 LogWIN with rear panels removed – rear view
Air control cable with Plug
X6/X7
Air control cable with
Plug X14
Lambda sensor cable
Cable channel
Low voltage
(230 V AC)
Air control
Cable channel
Extra-low voltage
(0–12 V DC)
Fig. 55 LogWIN control panel – top view
Plug for lambda sensor
Air control cable with
Plug X14
Air control cable with Plug
X6/X7
Flue gas sensor (accessories)
Plug X11
Connection for immersion
sleeve for thermal dis-
charge guard.
NOT stand-
ard – accessories