26
2.
For the installer
2.3.15 Installing the cable channels. routing the blower motor cable
and installing the sensor
– Attach the cable channels to the front of the control panel at left and right (feed-through at rear) with a drilling screw
on each side – Fig. 52.
– Route the sensor lines in the right cable channel towards the back – Fig. 52. Plug the flue gas sensor (accessories)
in the control panel into Plug X11 and also route it in the right cable channel toward the back. Route all sensor lines
through the feed-through in the cable channel downward.
– Insert boiler sensor and safety temperature limiter sensor (STB) as far as possible into the immersion sleeve and
secure them with the sensor guard to prevent them from slipping out – Fig. 53.
– Install the flue gas sensor with protective tube (accessories) into the flue outlet as described in the installation
instructions – Fig. 53.
– Route both cables for the flue gas blower in the cable channel towards the back – Fig. 52.
– Route the mains cable in the left cable channel towards the back and screw the power socket to the rear of the side
panel with 2 2.9x16 self-tapping screws – Fig. 53.
Fig. 52 Control panel. cable routing
Cable from lambda sensor
Boiler sensor and
STB sensor
Cable from flue gas blower
Flue gas sensor
(accessories)
Plug X11
Cable with
power plug
Cable from flue gas blower
Feed-through
1 x
1 x
Cable channels
Fig. 53 LogWIN – rear side
Flue gas sensor with
protective tube (accessories)
Boiler sensor
Sensor guard
STB sensor
Power socket
2 x
Note!
The immersion sleeve (not standard – accessories) for the thermal discharge safeguard must be installed
before the rear panels and before the boiled is filled.
Immersion sleeve for ther-
mal discharge guard.
NOT
standard – accessories