![Wilo Rexa BLOC Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/wilo/rexa-bloc/rexa-bloc_installation-and-operating-instructions-manual_982790038.webp)
38
WILO SE 10/2022 V05 DIN A4
English
TRANSPORTATION AND STORAGE
3.5.2.
Operating mode S2 (short-time duty)
The maximum operating period for the motor is specified in
minutes, e.g. S2-15. The pause must last until the machine
temperature no longer differs from the temperature of the
coolant by more than 2 K.
3.5.3.
Operating mode S3 (intermittent periodic duty)
This operating mode defines a combination of periods of
operation and standstill of the motor. With S3 operation,
the values given are always calculated based on a period of
10 min.
Example: S3 25 %
Operating time 25 % of 10 min = 2.5 min / standstill time
75 % of 10 min = 7.5 min
3.6.
Technical data
The following technical data can be found on the rating plate:
Max. delivery head:
H
max
Max. volume flow:
Q
max
Rated power required from
hydraulics:
P
2
Discharge connection:
X
-]
Suction connection:
[-
X
Fluid temperature:
T
Size of standard motor:
Type key
Standard speed:
N
Weight:
M
hydr
The total weight is calculated from the weight of the
hydraulics and the weight of the motor (see rating plate on
motor)!
The detailed motor data according to EU 2019/1781 can be
consulted via the motor’s article number here:
https://qr.wilo.com/motors
3.7.
Type key
Example: Wilo-Rexa BLOC-V08.52-260DAH132M4
BLOC
Series
V
Impeller shape
V = vortex impeller
C = single-channel impeller
M = multi-channel
08
Size discharge connection, e.g. 08 = DN 80
52
Internal performance indicator
260
Impeller diameter in mm
D
Flange connections
A = ANSI connection
D = DN connection
A
Material version
A = standard version
Y = special version
H
Installation type
H = horizontal
V = vertical
132 m
Construction size of standard motor
4
Number of poles for the necessary hydraulics
speed
Alternative type key
Example: Wilo-RexaBloc RE 08.52W-260DAH132M4
RE
Series
08
Size discharge connection, e.g. 08 = DN 80
52
Internal performance indicator
W
Impeller shape
W = vortex impeller
D = three-channel impeller
260
Impeller diameter in mm
D
Flange connections
D = DN connection
A = ANSI connection
A
Material version
A = standard version
Y = special version
H
Installation type
H = horizontal
V = vertical
132 m
Construction size of standard motor
4
Number of poles for the necessary hydraulics
speed
3.8.
Scope of delivery
•
Version:
•
Unit: Sewage hydraulics with built-on standard motor
•
“Bare shaft” version: Sewage hydraulics without
motor
• Transport shackle built onto the discharge port as
attachment point
•
Installation and operating instructions:
•
Unit: separate instructions for hydraulics and motor
•
“Bare shaft” version: Instructions for hydraulics
• CE declaration
3.9.
Accessories
• Connection cable, sold by the metre
• External pencil electrode for sealing chamber monitoring
• Level control devices
• Fixation accessories and chains
• Switchgear, relays and plugs
4.
Transportation and storage
NOTICE
Also note all the information regarding trans-
port and storage in the operating and mainte-
nance manual for the motor manufacturer!