PAGE 130 OF 164
PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM
OPERATING INSTRUCTIONS
TP-5580101-A
FEBRUARY 2022
6.3.2.1
Partial Extension Applications
This section describes applications using partial extension of the mast assuming the use of a
hold down platform and two hold down leashes (Section 3.3.5). Note that masts with 6.75-inch
base tubes only have and require one hold down leash.
For partial extension applications:
1. Install the hold down platform on top of the mast.
2. Secure a hold down leash to the hold down platform at a lug.
3. Secure a hold down leash to a guy lug on the desired mast collar. The guy lug on the desired
collar should be in-line with the lug on the hold down platform.
4. Secure the second hold down leash to the hold down platform at the lug opposite the first
hold down leash.
Содержание 10-60 HDL
Страница 2: ......
Страница 16: ...PAGE 14 OF 164 PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM OPERATING INSTRUCTIONS TP 5580101 A FEBRUARY 2022...
Страница 18: ...PAGE 16 OF 164 PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM OPERATING INSTRUCTIONS TP 5580101 A FEBRUARY 2022...
Страница 148: ...PAGE 146 OF 164 PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM OPERATING INSTRUCTIONS TP 5580101 A FEBRUARY 2022...
Страница 154: ...PAGE 152 OF 164 PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM OPERATING INSTRUCTIONS TP 5580101 A FEBRUARY 2022...
Страница 166: ...PAGE 164 OF 164 PNEUMATIC MAST WITH REMOTE LOCKING SYSTEM OPERATING INSTRUCTIONS TP 5580101 A FEBRUARY 2022...