Page 41
17333-15-0806
1. Remove glass door and place away from the fireplace.
2. Turn on gas shut off valve. Follow ignition procedure.
3. If burner does not light after spark sequence has ended, use an
insulated jumper wire (see page 40) between terminal locations
12 and 13 for fast reset function.
4. Interrupt power for 5 seconds. The green indicator light will
blink 4 times repetitively. Then retry for ignition.
5. Allow time for any raw gas to dissipate and repeat steps 3 and
4 until ignition is achieved.
6. Turn burner off and install glass door frame assembly.
7. Test ignition of burner with glass door in place.
FOR YOUR SAFETY READ BEFORE LIGHTING
Warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage,
personal injury, or loss of life.
A. BEFORE LIGHTING smell all around the heater area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any fireplace.
• Do not touch any electric switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the Fire
Department.
B. Use only the wall switch or remote control switch to turn the
gas control on/off. Any attempted repairs or adjustments should
be performed by a qualified service technician. Applying force
or any attempted repair may result in a fire or explosion.
C. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect the
heater and to replace any part of the control system and any gas
control which has been under water.
1. STOP! Read the safety information above.
2. Set the thermostat, if used, to the lowest setting.
3. Turn off electric power to the appliance.
4. This appliance is equipped with an ignition device that
automatically lights the burner. Do not try to light the burner
by hand.
ON
OFF
5. Lower louver front assembly.
6. Turn gas line valve to "ON."
7. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you do smell gas, STOP! Follow
“A” in the safety information above. If you do not smell gas,
go to the next step.
8. Close bottom louver assembly.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting (if available).
11. If the appliance will not operate, follow the instructions below
on how to turn off gas to heater, and call your service technician
or gas supplier.
1. STOP! Read the safety information above.
2. Set the thermostat, if used, to the lowest setting.
3. Turn off electric power to the appliance.
4. Open bottom louver assembly.
5. Turn gas line valve to “OFF.”
6. Close bottom louver assembly.
NOTE: UNIT MUST BE PROPERLY GROUNDED FOR ELECTRONIC IGNITION TO FUNCTION.
On initial installation, or after extended periods where the fireplace has not been used, gas lines may require purging.
The installer or qualified service person may use the following purge procedures to prevent the delays that would be caused by
waiting for the lockout periods between tries for ignition.
PURGE PROCEDURE
INSULATED
JUMPER WIRE
HOW TO TURN OFF GAS TO HEATER
LIGHTING INSTRUCTIONS
DIRECT IGNITION LIGHTING INSTRUCTIONS
INITIAL START UP GAS LINE PURGE