Page 7
17333-15-0806
Figure 1
Dim
DVD32
DVD36
DVD42
DVD48
A
34"
864mm
37"
940 mm
43"
1092 mm
49"
1245 mm
B
31"
787 mm
34"
864 mm
40"
1016 mm
46"
1168 mm
C
23 1/16"
585 mm
23 1/16"
585 mm
25 1/16"
636 mm
25 1/16"
636 mm
D
35 5/8"
905 mm
35 5/8"
905 mm
37 5/8"
956 mm
37 5/8"
956 mm
E
32 3/4"
832 mm
32 3/4"
832mm
34 3/4"
883 mm
34 3/4"
883 mm
F
16 3/8"
416 mm
16 3/8"
416 mm
16 3/8
416 mm
16 3/8"
416 mm
G
24 1/2"
622 mm
24 1/2"
622 mm
26 1/2"
673 mm
26 1/2"
673 mm
H
7 1/8"
181 mm
7 1/8"
181 mm
7 1/8"
181 mm
7 1/8"
181 mm
I
21 1/2"
546 mm
24 1/2"
622 mm
30 1/2"
774 mm
36 1/2"
927 mm
J
10 3/4"
273 mm
12 1/4"
311 mm
15 1/4"
387 mm
18 1/4"
464 mm
K
9 1/4"
235 mm
9 1/4"
235 mm
9 1/4"
235 mm
9 1/4"
235 mm
RIGHT SIDE VIEW
J
H
K
Remote Control
Options & Accessories
Description
FRBC
Millivolt Batt. Remote ON/OFF
FRBTC
Millivolt Batt. Remote T-Stat
FREC
Direct Ignition/Millivolt 120V ON/OFF Remote
TMW
Millivolt Wireless Wall Thermostat
TRW
Millivolt Reed Switch Wall Thermostat
FWS-1
Direct Ignition/Millivolt Wall Switch
Venting Options
Description
DVVK-4TS
Top vent kit (HORZ.) - 4½" to 6" (114.3mm to 152mm) wall
thickness
DVVK-4T
Top vent kit (horz.) - 8" to 12" (203mm to 305mm) wall thickness
DVVK-4R
Rear vent kit (horz.) - 5" to 7" (127mm to 178mm) wall thickness
DVVK-4V
Vertical vent kit
DVVK-4F
Horizontal flex vent kit (4' FLEX)
DVVK-4RE
Horizontal round termination (wall thickness up to 11 7/16")
DV822
Vinyl siding kit for DVVK-4RE
DVD32
DVD36
DVD42
DVD48
Input BTU/Hr Maximum
18,000
20,000
25,000
28,000
BTU/Hr Minimum (millivolt only)
14,000
14,000
18,000
20,000
KWH (Maximum)
5.3
5.9
7.3
8.2
(Minimum)
4.1
4.1
5.3
5.9
NAT.
Orifice
#46 (.081")
P-254
2.10 mm
P-288
#42 (.0935")
P-286
#39 (.0995")
P-285
Air Shutter Opening
1/16" (1.6mm)
1/16" (1.6mm)
3/16"(4.8mm)
1/8" (3.2mm)
LP
Orifice
#56 (.0465")
P-287
#55 (.052")
P-182
1.45 mm
P-208
#52 (.0635")
P-185
Air Shutter Opening
1/4" (6.3mm)
5/16" (7.9mm)
5/16" (7.9mm)
5/16" (7.9mm)
Height without standoff
32 3/4" (832mm)
32 3/4"(832mm)
34 3/4"(883mm)
34 3/4"(883mm)
Width
34" (864mm)
37" (940mm)
43" (1092mm)
49" (1245mm)
Depth
16 3/8" (416mm)
16 3/8" (416mm)
16 3/8" (416mm) 16 3/8" (416mm)
Gas Inlet Shutoff Valve (Pipe)
1/2 NPT
1/2 NPT
1/2 NPT
1/2NPT
NOTE: Air shutter settings
are factory minimum
settings. Some venting
configurations may
require minor air shutter
adjustments for optimum
performance
.
SPECIFICATIONS
FIREPLACE DIMENSIONS