Page 40
17333-15-0806
DIRECT IGNITION WIRING DIAGRAM
MAI
N
VAL
VE
RETURN
1 2
4
6
8
12
13
GROUND
120V
AC
RETURN
120V
AC
HOT
MAI
N
VAL
VE
HOT
120
VA
C
LINE
120
VA
C
RTN
GAS VALVE
CONTROL MODULE
JUNCTION BOX
BLACK
SPARK
IGNITOR
GREEN
LED LIGHT
WHITE
(OPTIONAL) ON/OFF WALL
SWITCH OR 120 VOLT
THERMOSTAT
(INSTALLER PROVIDED)
(OPTIONAL)
REMOTE CONTROL
RECEIVER
120V
(Wiring without remote)
LED CODES
Steady ON
Normal operation, power ON to control
2 Flashes
3 unsuccessful ignition trials
3 Flashes
Main burner flame failed 4 times during a single heating cycle
4 Flashes
5 minute lockout is complete. Interrupt power for 5 seconds to reset control
Steady Flash
Flame detected out of sequence
IF ANY OF THE ORIGINAL WIRE AS
SUPPLIED WITH THIS UNIT MUST BE
REPLACED, IT MUST BE REPLACED
WITH NUMBER 18, 150˚C WIRE OR ITS
EQUIVALENT.
OPTIONAL REMOTE CONTROL
Electric (120 volt) Operated Remote Control (FREC)
1. Disconnect 3-prong power cord from receptacle.
2. Remove wire from 120 VAC hot terminal on control module.
3. Connect female terminal from receiver onto 120 VAC hot
terminal on control module.
4. Connect remaining wire from remote control (male terminal)
to (female terminal) on power cord removed from control
module (step 2).
5. Insert electric remote control power cord plug into the
junction box on the right side of fireplace.
6. Connect 3-prong plug into receptacle. See wiring diagram on
page 49.
Figure 57