12
Operating this appliance out of level can cause DEATH, INJURY, and EQUIPMENT DAMAGE.
This appliance must be level both front-to-back and side-to-side in all installations.
NEVER operate this appliance out of level.
If this appliance is suspected to be out of level, shut it down at once and call your qualified
Cleveland Range authorized service agency immediately.
CHAPTER 6 GENERAL INSTALLATION INFORMATION
A. Inspect for Shipping Damage
•
If the appliance is damaged or damage is suspected:
1.
Submit a Damage Claim to the Shipper immediately.
2.
Inform your dealer at once.
3.
Inform Cleveland Range in writing within three (3) days.
CHAPTER 7 INSTALLATION
A. Select a Location
1.
For safe and efficient operation:
a.
Installation must comply with all local fire and health codes.
b.
The location selected must be capable of supporting this appliance.
•
The operating weight of a 24CGA10 is 780 lbs.
c.
Position the appliance so it will not tip or slide.
d.
The operating surface must be level enough to allow leveling with the adjustable legs.
This appliance
MUST
be level both front to back and side to side before operation.
e.
A suitable drain must be available within 12 feet of this appliance. Do NOT install the
appliance directly over a drain.
f.
The location must include space for Operating and Service/Secondary Clearances and
the Exhaust Hood. Refer to spec sheet for more details.
g.
KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLES.
h.
Proper air supply for ventilation and combustion is REQUIRED for and CRITICAL to safe,
efficient operation of this appliance.
i.
Make sure the air vents of this appliance are not blocked with or by anything.
All clearance requirements above, below, and around this appliance are the same for
non-combustible locations as for combustible locations.
Failure to maintain required clearances and additional distances as needed can result in
INJURY and EQUIPMENT DAMAGE.
Consult manufacturers’ literature, and sales and service agencies as needed.