24
g.
Check for steam leaks around the door gasket.
h.
Leave the ON/OFF switch in the ON position.
i.
Set the controls to stop steaming:
•
TIMER MODELS: Set the Timer to 0 (zero) minutes.
j.
If the control panel
does not have a timer
, complete Step l.
•
If the control panel
has a timer or a Door Interlock Switch,
skip Step 2. and go to the
appropriate test(s).
1) Turn the appliance OFF using the ON/OFF switch:
•
The red indicator in the ON/OFF switch turns OFF.
•
Automatic blowdown starts and runs for 3 minutes.
2) After blowdown ends:
a) Turn OFF the Main External Power Switch.
b) Replace all panels and sheeting.
c)
Turn ON the Main External Power Switch.
D. Timer Test for Dial Timer Control Panel
1.
Set the TIMED/MANUAL switch to MANUAL and let the appliance continue steaming.
2.
Zero the Timer by turning the dial counterclockwise until it points to 0 (zero).
Note: The buzzer will NOT sound in Manual Mode.
3.
Set the TIMED/MANUAL switch to TIMED.
a.
The buzzer sounds for 3 seconds.
b.
Steaming stops.
c.
Condenser flow stops.
4.
Open the cooking compartment doors, and
a.
Let the steam vent.
b.
Let the cooking compartments cool for 3 minutes.
5.
Close the cooking compartment doors.
6.
Turn the timer dial to 10 minutes.
•
The cooking compartments begin to heat.
7.
The condenser solenoid clicks open, condenser flow starts, and water flows from the drainpipe.
8.
The Boiler makes steam, and
•
The fill valve solenoid clicks and the fill valve opens and closes.
•
The water in the sight glass rises and falls as the Boiler and the fill valve operate.
9.
The Timer counts down to 0 (zero), and
a.
Condenser flow stops.
b.
The buzzer sounds for 3 seconds.
c.
Steaming stops.
10. Turn the ON/OFF switch to OFF:
a.
The red indicator turns OFF.
b.
The automatic blowdown cycle starts.
c.
The automatic blowdown cycle ends after 3 minutes.
d.
After blowdown ends:
(1) Turn OFF the Main External Power Switch.
(2) Replace all panels and sheeting.