27
•
Copies of purchase order(s) and invoice(s) for repair parts and service, maintenance, or
repair. Include part numbers, if applicable.
•
The name and signature of the person performing the service, maintenance, or repair.
C. Daily Maintenance
1.
Blowdown
•
Blowdown the steam generator. Follow the instructions in Chapter 5.
2.
Clean the Appliance
•
Clean the interior and exterior of the appliance. Follow the instructions in Chapter 5.
D. Weekly Maintenance
1.
Clean the Cooking Compartment Drains
•
Blockage of the drain line can cause pressure buildup in the compartment(s) resulting in
steam leaks around the door gasket(s), reduced performance, and compartment implosion.
2.
To inspect the drain screens and the drain lines for blockage:
a.
Clean the cooking compartment and drain screens. Follow the instructions in Chapter 5.
b.
Rotate the drain screen 90 degrees to inspect the drain opening.
c.
Clean the opening and put the screen back into their operating position.
d.
Pour a quart of water into the cooking compartment. If the water drains slowly or stands,
clean the cooking compartment drains with a NSF/FDA approved drain cleaner.
•
Follow the instructions of the drain cleaner manufacturer.
•
Flush the cooking compartments and drains with clean water.
E. Monthly Maintenance
1.
Descale the Steam Generator
•
Steam Generators should be descaled once a month, or more often depending on scale buildup.
•
Note the date of descaling in your maintenance and service records to help keep Steam
Generator descaling on schedule.
2.
SteamCraft Ultra 10 Descaling Procedure Using the Descaling Pump System
•
Cleveland Range recommends that your service agency descales your 24CGA10.
•
If you have trained and skilled in-house maintenance personnel, you may wish to discuss
purchasing Descaling Pump System P/N: 1071421 for use with Dissolve® Descaler Solution
P/N 106174 with your sales representative or service agency.
•
Use no other system of descaling.
3.
Manual Method to Descale Steam Generator
NOTE:
Part No. 106174 is the Part No. for a case (6 1-gallon containers) of
DISSOLVE
®
descaler..
THESE INSTRUCTIONS ARE FOR USE WITH
DISSOLVE
®
DESCALER SOLUTION
Cleveland Range Part Nos. 106174.
•
Health Hazard Data, Effects of Overexposure
–
This product may cause a burning sensation to eyes or skin.
•
Emergency and First Aid Procedures
–
In case of eye contact, immediately flush eyes with plenty of water.
–
If irritation persists, seek medical attention. In case of skin contact wash with soap and
water.