20
DO NOT TRY TO LIGHT BURNERS WITH A FLAME.
This appliance
has an electronic ignition system, which automatically lights burners, senses flame,
and controls gas flow.
Burners cannot be lit with a flame.
DEATH, INJURY, OR EQUIPMENT DAMAGE may result from trying to light burners with a flame.
BURN and SCALD HAZARD
Exposure to steam, condensate, and hot surfaces can cause death, burns, and scalds.
To help avoid injury:
•
Do NOT breathe steam or condensate.
•
Stand on the hinge side and away from the appliance and slowly open the cooking compartment door.
•
Open the door slightly to allow steam, condensate, and heat to vent before looking or reaching into the
cooking compartment.
•
Always wear DRY heatproof gloves when reaching into the cooking compartment or handling hot items.
Wet or damp gloves conduct heat and may cause burns when handling hot items.
Failure to follow these precautions can result in death, burns, and scalds.
CHAPTER 8 STARTUP PROCEDURE
Problems? See the Installer’s Troubleshooting Guide at the end of this manual.
Burner Ignition Test (Lighting and Shutdown Instructions)
NOTE: Perform this test before Startup Test Procedure
NOTE:
For new installations, or when air in gas lines is suspected, it may be necessary to bleed the air
from the gas lines. Bleed air as close as possible to the inlet of the automatic gas valve.
A. Lighting Instructions
(Test of function of pilot light and burner ignition system.)
1. If not already done:
a.
Test the water supply lines. (Leaks and pressure.)
b.
Test the gas supply lines. (Leaks and pressure.)
c.
Check that the ON/OFF valve of automatic gas control valve is in the ON position.
d.
Open the Main Manual Gas Valve.
2. Turn the Main External Power Switch OFF.
3. Control Panel Settings:
a.
MANUAL/TIMED Switch: TIMED. (If dial timer model.)
b.
TIMER DIAL: 0 minutes. (If dial timer model.)
4. Turn ON the electrical power to the appliance at the Main External Power Switch.
a.
When initial power is supplied to the appliance with the ON/OFF switch in the OFF position, a
3-minute automatic blowdown cycle starts.
b.
This cycle stops after 3 minutes OR when the ON/OFF switch is changed to the ON position.
5. Turn ON the electrical power to the appliance at the ON/OFF switch.