29
•
General precautions: wear rubber gloves, splash goggles and other protective clothing and
equipment as necessary. Refer to Dissolve® container labels and Material Safety Data Sheets for
information regarding eyewash, first aid, medical treatment, and spill control.
4.
Descaling Procedure
1) Turn steamer OFF and open door(s)
•
3 minute Automatic Blowdown cycle runs
2) Turn steamer ON
•
Generator begins to refill
3) Press TIMED end of TIMED/MANUAL switch (or for ON/OFF
Models put the ON/OFF selector Switch in the OFF Position)
4) DO NOT start timer,
DO NOT HEAT APPLIANCE
•
Water must be cold for descaling
•
Open cooking compartment door(s)
•
Leave cooking compartment door(s) open
5) Remove descaling port cap (see Figure 6-1)
6) Add required amount of Dissolve® through the descale port
while generator refills
•
Pour slowly to avoid overflow
•
Refill can take up to 8 minutes
•
Use 1 gallon Dissolve® for Ultra 5 gas
•
Use 1 ½ gallons Dissolve® for Ultra 10 gas
7) Add 1-2 gallons of cold tap water to descaling port after refill stops; continue to fill with cold water
until descaling solution enters cooking compartment(s) through steam nozzles
•
Note: Some descaling solution will flow from drain of Ultra 10 gas steamers
•
Adding extra water to generator(s) raises descaling solution to higher than normal water fill
level, allowing descaling solution to clean sensors and surfaces above normal water fill level
8) Let descaling solution soak in generator(s) for 1 hour
9) After 1 hour, turn ON/OFF switch OFF to start 3 minute Automatic Blowdown
•
This drains and rinses generator(s)
10) After Automatic Blowdown ends, turn ON/OFF switch to ON
11) Add cold tap water through descaling port after generator refills, until water enters cooking
compartment(s) through steam nozzles
•
This raises the water level to rinse the surfaces cleaned in Step 8
12) Turn ON/OFF switch OFF to start 3 minute Automatic Blowdown to rinse generator
13) Replace descaling cap and close cooking compartment door(s)
14) Turn TIMED/MANUAL switch to TIMED
15) Turn steamer ON/OFF switch to ON and set TIMER for 20 minutes
•
For Keypad Timer models: Press START/STOP key to begin the cook cycle
•
For ON/OFF models: Turn the steamer ON for twenty minutes
16) After the timer counts down, turn ON/OFF switch to OFF to start Automatic Blowdown
Figure 6-1
Descale Port