17
1) Test Water Supply Lines
a.
Check all connections for proper tightness.
b.
Remove the side panels to inspect the water connections inside the appliance.
c.
Open the water supply valves.
d.
Check all lines and connections for leaks, both inside and outside the appliance.
G. Electric Power Supply
•
The electric supply must match all electrical and wiring requirements specified on the rating plate.
•
NOTE: This appliance is
NOT
Ground Fault Interrupter (GFI or GFCI) compatible.
•
NOTE: The 24CGA10 Electrical Diagram is located inside of the Condensate Drip Trough.
The connection must be made as follows:
1.
Install a main disconnect switch and a separate fuse or breaker for this appliance as shown in
Figure 3-9.
The fused disconnect switch is referred to as the “Main External Power Switch.”
2.
Do not use a GFI (GFCI) circuit. This appliance is not GFI compatible.
3.
Do NOT use a power cord.
4.
Make the electrical connection using flexible conduit, per local code. See Figure 3-10.
Figure 3-10
Hardwire Connection
Power 10
DRAIN LINE
COLD WATER SUPPLY LINES
MAIN EXTERNAL
POWER SWITCH
Figure 3-9
Electrical Layout
This appliance is not GFI (GFCI) compatible.
Do not use a GFI (GFCI) circuit.
Using a GFI (GFCI) circuit can result in injury, equipment damage, and property damage.